The construction of the casing for the optical part of the Perla C laser system

The technical team in the HiLASE Centre implements tailor-made design solutions according to the requirements of our scientists. An example is the cabinet design for the optical part of the Perla C laser system. The task of the cabinet is to ensure constant operating conditions and maximum system accuracy. Therefore, an aluminum cast plates design was chosen. In a solid base plate a cooling system is produced using drilled channels. In order to optimize heat distribution, the system has 3 independent circuits.